Notifications
You must be signed in to change notification settings - Fork 78
Expand file tree
/
Copy path0001-xen-xenbus-better-handle-backend-crash.patch
More file actions
126 lines (115 loc) · 4.85 KB
/
0001-xen-xenbus-better-handle-backend-crash.patch
File metadata and controls
126 lines (115 loc) · 4.85 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
From c2b6a8e0c215ad574f49001994ab1ef661df57e1 Mon Sep 17 00:00:00 2001
From: =?UTF-8?q?Marek=20Marczykowski-G=C3=B3recki?=
<marmarek@invisiblethingslab.com>
Date: Thu, 9 Oct 2025 14:51:04 +0200
Subject: [PATCH] xen/xenbus: better handle backend crash
MIME-Version: 1.0
Content-Type: text/plain; charset=UTF-8
Content-Transfer-Encoding: 8bit
When the backend domain crashes, coordinated device cleanup is not
possible (as it involves waiting for the backend state change). In that
case, toolstack forcefully removes frontend xenstore entries.
xenbus_dev_changed() handles this case, and triggers device cleanup.
It's possible that toolstack manages to connect new device in that
place, before xenbus_dev_changed() notices the old one is missing. If
that happens, new one won't be probed and will forever remain in
XenbusStateInitialising.
Fix this by checking backend-id and if it changes, consider it
unplug+plug operation. It's important that cleanup on such unplug
doesn't modify xenstore entries (especially the "state" key) as it
belong to the new device to be probed - changing it would derail
establishing connection to the new backend (most likely, closing the
device before it was even connected). Handle this case by setting new
xenbus_device->vanished flag to true, and check it before changing state
entry.
And even if xenbus_dev_changed() correctly detects the device was
forcefully removed, the cleanup handling is still racy. Since this whole
handling doesn't happend in a single xenstore transaction, it's possible
that toolstack might put a new device there already. Avoid re-creating
the state key (which in the case of loosing the race would actually
close newly attached device).
The problem does not apply to frontend domain crash, as this case
involves coordinated cleanup.
Problem originally reported at
https://lore.kernel.org/xen-devel/aOZvivyZ9YhVWDLN@mail-itl/T/#t,
including reproduction steps.
Signed-off-by: Marek Marczykowski-Górecki <marmarek@invisiblethingslab.com>
---
I considered re-using one of existing fields instead of a new
xenbus_device->vanished, but I wasn't sure if that would work better.
Setting xenbus_device->nodename to NULL would prevent few other places
using it (including some log messages). Setting xenbus_device->otherend
might have less unintentional impact, but logically it doesn't feel
correct.
---
drivers/xen/xenbus/xenbus_client.c | 2 ++
drivers/xen/xenbus/xenbus_probe.c | 25 +++++++++++++++++++++++++
include/xen/xenbus.h | 1 +
3 files changed, 28 insertions(+)
diff --git a/drivers/xen/xenbus/xenbus_client.c b/drivers/xen/xenbus/xenbus_client.c
index e73ec225d4a61..ce2f49d9aa4ad 100644
--- a/drivers/xen/xenbus/xenbus_client.c
+++ b/drivers/xen/xenbus/xenbus_client.c
@@ -275,6 +275,8 @@ __xenbus_switch_state(struct xenbus_device *dev,
*/
int xenbus_switch_state(struct xenbus_device *dev, enum xenbus_state state)
{
+ if (dev->vanished)
+ return 0;
return __xenbus_switch_state(dev, state, 0);
}
diff --git a/drivers/xen/xenbus/xenbus_probe.c b/drivers/xen/xenbus/xenbus_probe.c
index 86fe6e7790566..3c3e56b544976 100644
--- a/drivers/xen/xenbus/xenbus_probe.c
+++ b/drivers/xen/xenbus/xenbus_probe.c
@@ -444,6 +444,9 @@ static void xenbus_cleanup_devices(const char *path, struct bus_type *bus)
info.dev = NULL;
bus_for_each_dev(bus, NULL, &info, cleanup_dev);
if (info.dev) {
+ dev_warn(&info.dev->dev,
+ "device forcefully removed from xenstore\n");
+ info.dev->vanished = true;
device_unregister(&info.dev->dev);
put_device(&info.dev->dev);
}
@@ -659,6 +662,28 @@ void xenbus_dev_changed(const char *node, struct xen_bus_type *bus)
return;
dev = xenbus_device_find(root, &bus->bus);
+ /* Backend domain crash results in not coordinated frontend removal,
+ * without going through XenbusStateClosing. Check if the device
+ * wasn't replaced to point at another backend in the meantime.
+ */
+ if (dev && !strncmp(node, "device/", sizeof("device/")-1)) {
+ int backend_id;
+ int err = xenbus_gather(XBT_NIL, root,
+ "backend-id", "%i", &backend_id,
+ NULL);
+ if (!err && backend_id != dev->otherend_id) {
+ /* It isn't the same device, assume the old one
+ * vanished and new one needs to be probed.
+ */
+ dev_warn(&dev->dev,
+ "backend-id mismatch (%d != %d), reconnecting\n",
+ backend_id, dev->otherend_id);
+ dev->vanished = true;
+ device_unregister(&dev->dev);
+ put_device(&dev->dev);
+ dev = NULL;
+ }
+ }
if (!dev)
xenbus_probe_node(bus, type, root);
else
diff --git a/include/xen/xenbus.h b/include/xen/xenbus.h
index 7dab04cf4a36c..43a5335f1d5a3 100644
--- a/include/xen/xenbus.h
+++ b/include/xen/xenbus.h
@@ -87,6 +87,7 @@ struct xenbus_device {
struct completion down;
struct work_struct work;
struct semaphore reclaim_sem;
+ bool vanished;
/* Event channel based statistics and settings. */
atomic_t event_channels;
--
2.51.0